Permanent Magnet Synchronous Motor Variable Frequency Converter Drive Pm VSD Inverter Direct Driven Double Screw Air Compressor with Affordable Price

Product Details
Customization: Available
After-sales Service: 24/7 After Sale Service
Warranty: 24/7 After Sale Service
Still deciding? Get samples of US$ 4899/Piece
Request Sample
Manufacturer/Factory, Trading Company
Gold Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
Importers and Exporters
The supplier has import and export rights
Full Customization
The supplier provides full customization services
Minor Customization
The supplier provides minor customization services such as logo, graphic, package
to see all verified strength labels (10)
  • Permanent Magnet Synchronous Motor Variable Frequency Converter Drive Pm VSD Inverter Direct Driven Double Screw Air Compressor with Affordable Price
  • Permanent Magnet Synchronous Motor Variable Frequency Converter Drive Pm VSD Inverter Direct Driven Double Screw Air Compressor with Affordable Price
  • Permanent Magnet Synchronous Motor Variable Frequency Converter Drive Pm VSD Inverter Direct Driven Double Screw Air Compressor with Affordable Price
  • Permanent Magnet Synchronous Motor Variable Frequency Converter Drive Pm VSD Inverter Direct Driven Double Screw Air Compressor with Affordable Price
  • Permanent Magnet Synchronous Motor Variable Frequency Converter Drive Pm VSD Inverter Direct Driven Double Screw Air Compressor with Affordable Price
  • Permanent Magnet Synchronous Motor Variable Frequency Converter Drive Pm VSD Inverter Direct Driven Double Screw Air Compressor with Affordable Price
Find Similar Products
  • Overview
  • FAQ
Overview

Basic Info.

Cooling System
Air Cooling
Power Source
AC Power
Cylinder Position
Vertical
Structure Type
Closed Type
Installation Type
Stationary Type
Type
Single Screw Compressor
Custom Service
Custom According Your Needs
Price
Competive Factory Price
Certificate
CE ISO and Factory Test Report
MOQ
1 Piece
Transport Package
Woodpackaing
Specification
1110*860*1310
Trademark
MUQI
Origin
China
HS Code
8414200000
Production Capacity
3000per Month

Product Description

Permanent Magnet Synchronous Motor Variable Frequency Converter Drive Pm VSD Inverter Direct Driven Double Screw Air Compressor with Affordable PricePermanent Magnet Synchronous Motor Variable Frequency Converter Drive Pm VSD Inverter Direct Driven Double Screw Air Compressor with Affordable PricePermanent Magnet Synchronous Motor Variable Frequency Converter Drive Pm VSD Inverter Direct Driven Double Screw Air Compressor with Affordable Price
Model Power(Kw) Free air delivery(m3/min) Weight(kg) size(mm) Pipe Diamater
0.6Mpa 0.7MPa 0.8MPa 1.0MPa length width height
MQ37DA
37
8.8
8.4
8
7.1
1500
2380
1300
1590
DN50
MQ45DA
45
11.8
11.4
10.7
9.4
1750
2380
1300
1590
DN50
MQ55DA
55
14.2
13.7
12.7
11.7
1750
2380
1300
1590
DN50
MQ75DA
75
17
16.3
16.1
12.8
2650
2900
1650
1850
DN65
MQ75DW
75
17
16.3
16.1
12.8
2430
2400
1650
1850
DN65
MQ90DA
90
23.5
22.3
20.6
18.5
2680
2900
1650
1850
DN65
MQ90DW
90
23.5
22.3
20.6
18.5
2490
2400
1650
1850
DN65
MQ110DA
110
26
25
24
22
2700
2900
1650
1850
DN65
MQ110DW
110
26
25
24
22
2600
2400
1650
1850
DN65
MQ132DA
132
30
29
28
24.5
3340
3100
1800
1950
DN80
MQ132DW
132
30
29
28
24.5
2960
2650
1800
1950
DN80
MQ160DA
160
35.5
34.5
33.8
31
3360
3100
1800
1950
DN80
MQ160DW
160
35.5
34.5
33.8
31
3180
2650
1800
1950
DN80
MQ185DA
185
41
38.5
36
32
4400
3600
1900
2050
DN100
MQ185DW
185
41
38.5
36
32
3650
3000
1900
2050
DN100
MQ200DA
200
42
41
40
34
4400
3600
1900
2050
DN100
MQ200DW
200
42
41
40
34
3700
3000
1900
2050
DN100
MQ220DA
220
50
46.5
45
40
5120
4100
2255
2300
DN125
MQ220DW
220
50
46.5
45
40
4550
3250
2255
2300
DN125
MQ250DA
250
58
55
53
43
5120
4100
2255
2300
DN125
MQ250DW
250
58
55
53
43
4550
3250
2255
2300
DN125
Permanent Magnet Synchronous Motor Variable Frequency Converter Drive Pm VSD Inverter Direct Driven Double Screw Air Compressor with Affordable PricePermanent Magnet Synchronous Motor Variable Frequency Converter Drive Pm VSD Inverter Direct Driven Double Screw Air Compressor with Affordable PricePermanent Magnet Synchronous Motor Variable Frequency Converter Drive Pm VSD Inverter Direct Driven Double Screw Air Compressor with Affordable PricePermanent Magnet Synchronous Motor Variable Frequency Converter Drive Pm VSD Inverter Direct Driven Double Screw Air Compressor with Affordable PricePermanent Magnet Synchronous Motor Variable Frequency Converter Drive Pm VSD Inverter Direct Driven Double Screw Air Compressor with Affordable PricePermanent Magnet Synchronous Motor Variable Frequency Converter Drive Pm VSD Inverter Direct Driven Double Screw Air Compressor with Affordable PricePermanent Magnet Synchronous Motor Variable Frequency Converter Drive Pm VSD Inverter Direct Driven Double Screw Air Compressor with Affordable Price
FAQ
   Operation Instructions:
A:Before Operation:
  1. Confirm the voltage of the power supply and the power indicator light is lit.
  2. Please open the leak valve of the oil & gas tank, drain the condensed water and immediately close the leak valve when oil leaks out.
  3. Please check the oil level and keep it between indicator oil level.
  4. Water cooled system , confirm that cooling water supply is normal.
  5. When generator driving the belt, please check the belt tension correctly, not too loose or too tight.
B:Start up
  1. Main power switch in.
  2.  Press the start button to turn on the motor, working indicator light is on.
  3. Check the discharge pressure gauge and lubricating oil pressure gauge are in correct indication.
C:Operation
  Please keep the exhaust temperature between 75ºC-95ºC to avoid condensation and precipitation and emulsify the oil.
D:Stop
  1. Press the "off" button, about 10-15 seconds later, the delay electromagnetic valve acts, and the compressor stops running.
  2. Turn off the power.
  3. Don't use the emergency stop button in case of non emergency.
E: Precautions:
  1. For initial start-up and after motor maintenance, determine the running direction of the press (as indicated by the arrow).
  2. Do not mix different brand of river lubricating oil.
  3. Change the consumables, lubricating oil and detail operation method, please refer the instruction manual.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier